Timeline

KeContact P40 & P40 Pro

Phase wise roll-out plan for the KeContact P40 & P40 Pro

Both the KeContact P40 and the KeContact P40 Pro are rolled out in different hardware variants. A distinction is made between the following hardware variants:

  • P40
  • P40 MID variant
  • P40 Pro MID variant
  • P40 MessEV variant
  • P40 Pro MessEV variant

Hardware versions cannot be updated automatically (unlike the software versions)

Each hardware variant can be updated to the latest software version.

Additional functions are added with each software version (1.1.0., 1.2.0 and 1.3.0.).
As soon as a new software version is available, this is communicated via push notification in the KEBA eMobility app.

Both the range of functions and the planned date of completion can be seen in the table below.

Timeline

 KeContact P40
variant
from November 2024
KeContact P40
MID-variant
from November 2024
KeContact P40 Pro
MID-variant
from Q1 2025
KeContact P40
MessEV-variant
from Q1 2025
KeContact P40 Pro
MessEV-variant
from Q1 2025
Equipment (ex works)
Hardware
Cable & plug6m Type 2 cable
(EN 62196-1, VDE-AR-E 2623-2-2)
6m Type 2 cable
(EN 62196-1, VDE-AR-E 2623-2-2)
6m Type 2 cable
(EN 62196-1, VDE-AR-E 2623-2-2)
6m Type 2 cable
(EN 62196-1, VDE-AR-E 2623-2-2)
6m Type 2 cable
(EN 62196-1, VDE-AR-E 2623-2-2)
height/width/depth476 mm / 221 mm / 142 mm476 mm / 221 mm / 142 mm476 mm / 221 mm / 142 mm476 mm / 221 mm / 142 mm476 mm / 221 mm / 142 mm
1-phase/3-phase
Power rating
1-phase/3-phase
7,4 kW / 11 kW7,4 kW / 22 kW7,4 kW / 22 kW7,4 kW / 11 kW7,4 kW / 22 kW
RCCB Type A + RDC-DD
RFID
WLAN
LTE optional   
ISO 15118 Hardware ready   
Software Version 1.1.0.
(from November 2024)
RFID authorization
PV excess charging
OCPP 1.6
Modbus TCP
UK SCPR
(Smart Charge Point Regulation)
Software Version 1.2.0.
(from Q1 2025)
Integrated phase switching
EMS integration via Modbus TCP
Fast Charging Button
X1 control according to §14a*
P40 as client in M20 loadmanagement
Software Version 1.3.0.
(from Q3 2025)
Loadmanagement via X1/X2
Modbus RTU meter integration
TOR for operators and users
There was an error

Please contact us directly via email at [email protected].

Your request was submitted successfully

Thank you for your request. Our KEBA Customer Support will get in touch with you soon.

Contact us

Need more information, have a question or want to report a problem? We will help you with your query!

First Name is a required field
Last Name is a required field
Email is a required field Please enter an email address
Subject is a required field
Message is a required field
 
Please select your preferred language
Your browser is out of date
Internet Explorer is no longer supported. Please switch to a current browser to use keba.com to its fullest extent.

Edge

Chrome

Safari

Firefox

KEBA - Automation by innovation.